bjtrott (ID: 431933)
Samples:
|
|
|
Engineering & CAD
|
|
Earnings (Year):
$0
|
|
|
|
Loading Overview...
|
Summary
|
| Member Since: |
|
| Last Signed in:
|
| Location: |
|
| Would work on site: |
|
| Earnings (All Time): |
|
Earnings by Skill (Year): |
|
Feedback |
| Rate: |
Min. Rate: | Min. Budget: |
Work Terms |
| Industries: |
|
|
|
Highlights
|
|
|
|
Skills
|
| Years of Experience: |
|
| Highest degree: |
|
| Software Skills: |
|
| Additional Skills: |
|
| Tested Skills: |
 |
|
|
Work Terms
|
|
|
|
|
| |
Description: |
Details: |
|
|
|

Download
|
|
Name:
Ground Water Remediation SCADA
380392_default_file_330.txt
Description:
Designed and developed a ground water remediation system that extracts contaminated ground water from 10 distributed wells around a chemical production facility (Osmose Wood Preserving, Inc.). The system is designed to extract water at given intervals and for any combinations of well configurations to a chemical holding tank. This system is the first stage of a chemical extraction process that is used to pressure impregnates the chemical into lumber. The system monitors ground water flow, current flow rates, volume, pump activation times and traps hardware failures 24hrs
|
|
Industry:
Chemicals & Materials
Price:
$10,000 to $25,000
|
|
|

Download
|
|
Name:
Environmental Chamber SCADA
380392_default_file_329.txt
Description:
This system was designed for an indoor air quality firm that provides product emissions testing using environmental chamber technology. This state of the art system uses computer controller based object oriented software to capture, in real time, interior and exterior environmental conditions of pressure, air temperature, relative humidity, and airflow. This data is used to analyze product emissions of chemicals as the chamber reproduces the conditions of the environment the product is used in. As the control software is capturing all of this information it is simultaneo
|
|
Industry:
Health Care
Price:
$10,000 to $25,000
|
|
|

Download
|
|
Name:
Pneumatic Source Transfer Sys.
380392_default_file_331.txt
Description:
A pneumatically driven radiation source transfer system was developed and produced for the Department of Energy of the United States. This system employed latest technology in servo motor positioning and optoelectric position monitoring within a radiation source transportation system. The system performs precise positioning of nuclear sources to remote locations for use in calibration of radiation measurement instruments and personal dosimeter devices. The system was implemented along with a 16 axis linear and rotational positioning system that achieves 100% repeatable r
|
|
Industry:
Government
Price:
Over $25,000
|
|
|

Download
|
|
Name:
Safety Control System
380392_default_file_325.txt
Description:
Designed and implemented a safety control system for authorized area entrance and protection. The system consisted of optical door interlocks, motorized actuated doors and lighting systems interfaced into a main computer controller. This system was designed for protection of unauthorized entrance into a high radiation environment, and to log any entrance or breach of interlock.
|
|
Industry:
Government
Price:
$2,500 to $5,000
|
|
|

Download
|
|
Name:
Pneumatic Transfer System
380392_default_file_324.txt
Description:
Below Grade Pneumatic Transfer System:
A rapid air delivery system was developed for radioactive sources to be used in calibration laboratories. Fail safe design with cost effective construction. Employs pneumatic valves that are electromechanically actuated to drive a radioactive rabbit from one location to another through tygon tubing. There are nine sources that can be transferred to any one of four destinations, which are selected by adjusting the diverter valve. A stepper motor and optical encoder positioning system that is governed by the controller software c
|
|
Industry:
Energy
Price:
Over $25,000
|
|
|
|
|
|
|
<
|
The Freelancer has not uploaded images.
|
>
|
|
|
|
My Account URL
|
|
Contact this Freelancer Now!
The Freelancer has opted to hide his/her contact information.
|
|
Instant Messenger
|
|
The Freelancer has not entered IM information.
|
|
Global Region
|
| Country: |
|
United States |
| GMT: |
|
(GMT-05:00) Eastern Time (US & Canada) |
| Local Time: |
|
12:13 AM |
|
|
|
|
|
| Profile |
|
|
|